Product Details:
Payment & Shipping Terms:
|
Product Name: | Ozone Aging Ozone Chamber Price Ozone Aging Test Machine Rubber Ozone Aging Test Chamber | Temperature Range: | 0℃~60℃ |
---|---|---|---|
Temp. Deviation: | ≤±2℃(No Load, Constant State) | Working Volume: | W400 X H500 X D400mm |
Temp.fluctuation: | ±0.5℃(No Load, Constant State) | Ozone Concentration: | 50~1000pphm(±10%) |
Power Supply: | About 3.0KW, 220V±10%V;50Hz | Customized Support: | OEM ODM OBM |
High Light: | OBM ozone aging test chamber,ODM ozone aging test chamber,ASTM1149 electronic test equipment |
Ozone Aging Ozone Chamber Price Ozone Aging Test Machine Rubber Ozone Aging Test Chamber
Function
Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method.
Standard
ASTM1149 HG/T2869 GB/T7762 GB/T136421
Main technical parameters
Item | Content |
working volume |
W400 X H500 x D400mm |
Outline dimension |
W1050 X H1680 x D1000mm |
Temperature range | 25℃~60℃ |
Temp. deviation | ≤±2℃(No load, constant state) |
Temp.fluctuation | ±0.5℃(No load, constant state) |
Humidity range | 50~75%RH(No load) |
Ozone concentration | 50~1000pphm(±10%) |
Air flow amount |
20~70L/min |
Air flow rate |
12~16mm/s |
Power supply | About 3.0KW, 220V±10%V;50Hz |
Running power | About 1—3.0KW |
Power line | 5 meters |
System composition:
1. Air circulation regulation
2. Heating system
3. Refrigeration system
4. Ozone detection system
5. Control system
6. Security protection devices
Key component configuration
No. | Material name and model | Unit | Qty | Specification or model |
1 | Outer container | 1.2mm | Electrostatic spray molding of stainless steel A3 plate | |
2 | Inner box | 1.0mm | SUS304 stainless steel wire drawing | |
3 | Heat insulating material | glass fibre | ||
4 | Heating element (1.2KW) | root | 2 | Stainless steel (fin type) |
5 | Sealing material | silastic | ||
6 | Air duct circulation system | |||
A.Electric motor(25W) | set | Sino-foreign joint venture YDK-25-4D | ||
B.Wind blade | peace | ф158-H82-ф8 | ||
7 | Control system | |||
Temperature controller | set | 1 | “TEMI880”(touch screen) | |
Temperature sensor | root | 2 | PT100 | |
Solid state relay | piece | 2 | British "Cutons" | |
Midget relay | piece | 4 | "Omron." | |
AC contactor | piece | 3 | Schneider. | |
Thermal relay | piece | 2 | Schneider. | |
Button switch | piece | 2 | "one open." | |
Overtemperature protector | piece | 1 | “OYO” | |
High-tension relay | piece | 2 | P30ME | |
Circuit breaker | piece | 2 | Dressie. | |
8 | Refrigeration system | |||
Compression engine | set | 1 | Japan"Panasonic." | |
Condensator | set | 1 | Shanghai "Beifeng" | |
Evaporimeter | set | 1 | custom made | |
9 | Humidifying system | |||
Humidifying system | root | 1 | PT100 | |
Humidifying pipe | piece | 3 | Taizhou | |
Small water pump | piece | 1 | Atman306 | |
Liquid level switch | piece | 2 | "Deep lattice" electron | |
10 | Standard Configuration Accessories | |||
A,headlamp | piece | 1 | FSL 9W | |
B,Windows glass | piece | 1 | Guangdong Pei Xin | |
C,Frozen solenoid valve | piece | 4 | "Casto"1028-3 | |
D,device for drying and filtering | piece | 2 | "Egg."EK083S | |
E, instrument connection | piece | 1 | 50㎜ | |
F,pressure gage | piece | 2 | FRG-250 | |
G,specimen holder | piece | 1 | stainless steel | |
11 | Ozone generation system | |||
Ozone sensor | piece | 1 | British imports | |
Ozone controller | Set | 1 | Korea“TEMI” | |
12 |
Protector
|
1. Overtemperature alarm protector 2. Humidification system water shortage protection 3. Fast fuse 4. Line fuse and full sheathed terminal 5. underphase protection 6. compressor high and low pressure protection 7. compressor overheat protection 8. compressor overcurrent protection |
||
13 | Document information | Operation and maintenance manual 1, qualification certificate 1, after-sale guarantee card 1, instrument specification 1 |
Contact Person: Ms. Zoe Bao
Tel: +86-13311261667
Fax: 86-10-69991663