Send Message
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Beijing Jinshengxin Testing Machine Co., Ltd.
Home ProductsDifferential Scanning Calorimetry Machine

0.1mW Oxidation Induction Time Test Machine For Plastic Analysis

China Beijing Jinshengxin Testing Machine Co., Ltd. certification
China Beijing Jinshengxin Testing Machine Co., Ltd. certification
Thanks for your help for Electronic Universal Testing Machine products

—— Gabriela

It has been a pleasure working with you, and I greatly appreciate the effort you’ve put collaborations between our companies. I hope the partnership between two companies will be further strengthened. I wish you all the best and success in the future.

—— Mr. Si Thu

I'm Online Chat Now

0.1mW Oxidation Induction Time Test Machine For Plastic Analysis

0.1mW Oxidation Induction Time Test Machine For Plastic Analysis
0.1mW Oxidation Induction Time Test Machine For Plastic Analysis
video play

Large Image :  0.1mW Oxidation Induction Time Test Machine For Plastic Analysis

Product Details:
Place of Origin: BEIJING, CHINA
Brand Name: JINHAIHU
Certification: ISO9001
Model Number: DSC-500A
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Packaging Details: Carton
Delivery Time: 5~10 work days
Payment Terms: T/T, L/C, Western Union, MoneyGram, D/A, D/P
Supply Ability: 20 sets per month
Detailed Product Description
Product Name: Oxidation Induction Time Tester For Plastic Analysis Temperature Range: Room Temperature To 500 ℃
Temperature Resolution: 0.1 ℃ Heating Rate: 0.1 ~ 80 ℃ / Min
DSC Range: 0 ~ + 500 Mw DSC Resolution: 0.01 MW
DSC Sensitivity: 0.1mW
High Light:

plastic oxidation induction time test machine

,

0.1mW oxidation induction time test machine

,

oxidation induction time test machine 0.1mW

Oxidation induction time tester for plastic analysis

Application:

  • Differential scanning calorimetry (DSC) methods for the thermal analysis of polymers and polymer blends, such as
  • - thermoplastics (polymers, moulding compounds and other moulding materials, with or without fillers, fibres or reinforcements),
  • - thermosets (uncured or cured materials, with or without fillers, fibres or reinforcements), and
  • - elastomers (with or without fillers, fibres or reinforcements).
  • Differential scanning calorimetry (DSC) is intended for the observation and measurement of various properties of, and phenomena associated with, the above-mentioned materials, such as
  • - physical transitions (glass transition, phase transitions such as melting and crystallization, polymorphic transitions, etc.),
  • - chemical reactions (polymerization, crosslinking and curing of elastomers and thermosets, etc.),
  • - the stability to oxidation, and
  • - the heat capacity.

The instrument features:

  • LCD liquid crystal blue backlight display, display information is very more, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, all kinds of switch state
  • USB communication interface, universality, communication and reliable don't interrupt, support from recovery connection function.
  • Furnace body structure is compact, Temperature rise rate arbitrary adjustable. To improve the installation process, all adopt mechanical fixed way, completely avoid the furnace internal colloid to differential thermal signal pollution.
  • Double temperature probe, ensure that the height of the sample temperature measurement repeatability. The temperature probe installed in the furnace wall, used in PID control the whole furnace temperature, but due to the temperature of the thermal inertia, conduction to the temperature of the sample has certain deviation, and the deviation degree of four seasons are different, therefore, by a single temperature probe temperature control and temperature measuring, whether differential thermal signal or temperature signal, the error is large; The instrument in the sample bottom install a temperature probe to measure the real temperature of the sample, and use our special temperature control technology, control furnace wall temperature makes the sample temperature reach setting temperature.
  • Digital gas mass flow meter automatic switching two way atmosphere flow, switching speed, stable time is short.
  • Mark with standard samples, the convenience of our customers correction constant temperature coefficient.
  • Furnace cooling interface, the convenience of our customers rapid cooling.
  • Software adaptive each resolution computer screen, the software automatically according to the computer screen size adjust every curve display mode. Support notebook, desktop, Support Win2000, XP, VISTA, WIN7 operating system, etc.
  • Support user programming procedures, to realize the automation of measuring steps. The software provides dozens of instruction, the user can according to your own measurement steps, agile combination each instruction, and save. Complex operation is simplified into a key operation.

0.1mW Oxidation Induction Time Test Machine For Plastic Analysis 0

 

0.1mW Oxidation Induction Time Test Machine For Plastic Analysis 1

Technical para

Temperature range Room temperature to 500 ℃
Temperature resolution 0.1 ℃
Heating rate 0.1 ~ 80 ℃ / min
DSC range 0 ~ + 500 mw
DSC resolution 0.01 mW
DSC sensitivity 0.1 mW
Working power supply AC 220V 50Hz
PC interface USB

 

Contact Details
Beijing Jinshengxin Testing Machine Co., Ltd.

Contact Person: Ms. Zoe Bao

Tel: +86-13311261667

Fax: 86-10-69991663

Send your inquiry directly to us (0 / 3000)