Product Details:
Payment & Shipping Terms:
|
Product Name: | PVC PPR PE Plastic Pipe Hydrostatic Pressure Testing Equipment | Model: | XGY-10C |
---|---|---|---|
Max. Pressure: | 10MPA, 100BAR, 16MPA, 160BAR, 20MPA, 200BAR | Pressure Resolution: | 0.01MPA, 0.1BAR |
Test Stations: | 3, 5, 10, 15, 20, 25, 30, 50 Can Customized | Temp. Range: | 15-95 ℃ |
Constant Pressure Accuracy: | -1%~+2% | Material Of Water Tank: | 304# Stainless Steel |
Material Of End Caps: | 304# Stainless Steel Or Carbon Steel | Power: | AC380V ±10% ,50/60Hz |
Standards: | ISO 1167, ASTM D1598/1599 | ||
Highlight: | ppr pipes hydrostatic testing machine,pvc pipes hydrostatic pressure testing machine,100 bar hydrostatic testing machine |
PVC PPR PE Plastic Pipe Hydrostatic Pressure Testing Equipment
Pro
Ⅰ. Summary:
The PVC PPR PE Plastic Pipe Hydrostatic Pressure Testing Equipment is used to maintain the pipe or pipe fittings in a certain pressure range for long-term internal pressure test, in the test pipe or pipe fittings ruptured or completed automatically stop, and can save the pressure curve and print the test report. In terms of control: Fill pressure and pressure relief by filling pressure and discharge pressure solenoid valve open to execute, steady pressure mainly through the control of filling pressure and discharge pressure solenoid valve point move open to achieve the effect of precise control, this machine has the automatic constant voltage, electric pressure relief, cleaning, and the function of automatic calibration, the equipment is imported from the other electromagnetic valve, unique sealing structure, when the water clean, To ensure the sealing and durability of the solenoid valve, is a kind of economic and practical, functional variety, high degree of automation testing machine. The instrument is widely used in various plastic pipe internal pressure test, suitable for building materials industry, pipe production units, national testing departments and scientific research units.
Ⅱ. System Feature:
1. Industrial chip control, direct control.
2. The machine and "precision pressure control unit" multi-channel combination.
3. Each station is independently controlled without interference.
4. 3 stations, 6 stations, 15 stations, 20 stations and other multiple stations can be selected, up to 60 stations and above. There are hydrostatic test and blasting test.
5. Max. pressure: 10, 16, 20MPa ...
6. Pipe diameter range: Φ16 ~ 2000mm can customized.
7. A microcomputer controls a working position, and the pressure, accuracy, time and other parameters can be set and controlled independently when the computer is not working. Real-time display of pressure, time and status (8 states: pressure rise, pressure compensation, pressure release, overpressure, run, test end, leak, burst), and store these test data. In case of overpressure, end of test, leakage, burst and so on, it has sound and light alarm function.
8. Power protection, test report storage/printout and other functions. Automatically determine the valid time, invalid time, remaining time and other parameters to prevent the invalid time and invalid time in the evening, holidays and other time periods.
9. When powering off the device, ensure that the test is accurate and successful. The instrument has reasonable structure, stable performance, convenient operation and intuitive display.
10. Rich software interface (multi-language environment, to meet customers in different countries and regions.
Ⅲ. Meet standards:
ISO1167, ISO9080, EN921, ASTMD1598, ASTMD1599 ISO13479.
Model | XGY-10C | |
Max.pressure | 10MPa | |
Test stations | 3, 5, 10, 15, 20, 25, 30, 50 can customized | |
Control mode | computer control | |
Data preservation | Each station has power off data protection function, boot can be restored | |
Time | timing time | 0~9999 h 59 min |
Timing accuracy | ±0.1% | |
time resolution | 1s | |
Minimum Set Unit | min | |
Pressure | Pressure control range | 0.2~10MPa |
Pressure indicator units | MPa,bar or PSI | |
Pressure control accuracy | -1%~ +2% | |
Constant Voltage Control Precision of Full Load Range | Within ±1% | |
Pressure display resolution | 0.001MPa,0.01bar or 1PSI | |
measuring range | 4%~100%FS | |
Allowable error limit for indication | Within 1% | |
Temperature | Control Range(with Refrigeration system) | 15-95℃ |
Control accuracy | ±0.5℃ |
Ⅴ. Configuration:
1. Pressure control host;
2. Pressure station;
3. End caps;
4. Water tank;
5. Refrigeration system.
Contact Person: Ms. Zoe Bao