Product Details:
Payment & Shipping Terms:
|
Product Name: | Hydrostatic Pressure Testing Machine For Long Term Test 1000 Hr And Short Term Test Of 1 Hr | Model: | XGY-10C |
---|---|---|---|
Max. Pressure: | 10MPA, 100BAR, 16MPA, 160BAR | Pressure Resolution: | 0.01MPA, 0.1BAR |
Test Stations: | 5, 10, 15, 20, 25, 30, 50 Can Customized | Temp. Range: | 15-95 ℃ |
Constant Pressure Accuracy: | -1%~+2% | Material Of Water Tank: | 304# Stainless Steel |
Material Of End Caps: | 304# Stainless Steel Or Carbon Steel | Standards: | ISO 1167, ASTM D1598/1599, ISO 4427 |
Highlight: | 100bar hydrostatic pressure testing machine,iso 1167 hydrostatic pressure testing machine,hydrostatic pressure testing machine for pipes |
Hydrostatic pressure testing machine for long term test 1000 hr and short term test of 1 hr
Ⅰ. Overview:
Hydrostatic pressure testing machine for long term test 1000 hr and short term test of 1 hr is suitable for the determination of damage resistance time of thermoplastic pipeline under instantaneous hydraulic blasting and long-term constant pressure. It is an indispensable testing instrument for scientific research institute, quality inspection department and pipe material production enterprises. The water pressure testing machine adopts computer embedded control. Modular design with independent control. If any problem occurs, as long as the cut-off valve at the current station is closed, it will not affect the normal operation of other stations. It has the functions of pipe fracture recognition, real-time monitoring, call data recovery, printing, test result storage, sample pretreatment setting and so on. Such a feature, and according to the needs of national holidays, can store up to 7 days of data. This machine is widely used in the internal pressure test of various plastic tubes, which is an ideal testing equipment for building materials industry, pipe manufacturing factory, national inspection department and scientific research department..
Ⅱ. System Feature:
1. Industrial tablet control, direct control.
2. The machine is combined with the "precision pressure control unit" multi-channel.
3. It is controlled both by PC and “Precision Pressure Controlling Unit”.
4. Every station controls separately. The most station can reach 100.
5. It can do hydrostatic test, burst test, 8760 test and so on.
6. The pressure can be from 3 to 100MPa.
7. It can distinguish eight testing condition including pressure up, pressure down, pressure compensation, pressure exceeding, running, ending, leakage, and exploding. And also it can judge both effective and ineffective time parameters automatically. (The effective time means the time of the pressure within the setting pressure.)
Ⅲ. Standards
ASTM D1598-2015 Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure
IS01167-2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids --Determination of the resistance to internal pressure -- Part 1: General method
ASTM D1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings 1
Pipe diameter range | Φ10~Φ1800mm | |
Working stations | 5, 10, 15, 20, 25, 30 or 50 can customized | |
Operation mode | PC control | |
Pressure range | 0.2~10MPa (or customized) | |
Pressure resolution | 0.001MPa, 0.01Bar | |
Pressure control accuracy range | -1%~+2% | |
Measuring range | 5%~100% F.S. | |
Timing range | 1s~9999H 99M 99S | |
Timing accuracy | ±0.1% | |
Display resolution | 1s | |
Min. Time setting unit | min | |
Temperature control system |
15~95℃ with cooling system |
|
Temperature control accuracy | ±0.5℃ | |
Power supply | 380V, three-phase four-wire system |
Ⅴ. Configuration:
1. Pressure control host;
2. Pressure source;
3. End caps;
4. Water tank;
5. Refrigerating system.
Ⅵ. Test conditions:
Ambient temperature: within 10℃ to 40℃
Relative humidity: within 30% to 80%
There shall be no vibration, no corrosive media in surrounding environment .
It shall be correctly installed on stable platform.
There shall be no strong magnetic interference, no strong air convection .
Exhaust system shall be installed in site in case of water vapour corrosion .