Product Name: | Thermoplastics Pipes For The Conveyance Of Fluids-Resistance To Internal Pressure-Test Method | Control Mode: | Computer And Meter |
---|---|---|---|
Stations: | 2, 3, 4, 5, 6, 8, 10, 12 Stations(can Customize) | Meet Standard: | ISO1167, ISO9080, EN921, ASTMD1598, ASTMD1599 ISO13479 |
Max. Pressure: | 16Mpa(can Be Customized) | End Caps: | Diameter From Φ6mm To Φ2000mm |
Temperature Range: | 15℃-95℃ | Pressure Unit: | MPA, PSI, Bar |
Temperature Unit: | ℃, ℉ | ||
High Light: | thermoplastics pipes internal pressure test,ISO1167 internal pressure test,internal pressure test iso1167 |
Thermoplastics pipes for the conveyance of fluids-Resistance to internal pressure-Test method
I. Function & Applications
XGY-16B Hydrostatic blasting tester is suitable for the determination of hydraulic instantaneous blasting and long-term constant pressure failure time of thermoplastic pipes for various fluid conveying plastic pipes. It is a necessary testing instrument for scientific research institutes, quality inspection departments and pipe manufacturers.
This series is the latest model, using microcomputer control technology, with test parameters set storage, display printing curve, real-time analysis, experimental report output and other functions.The software running Windows system. According to national standards, international standards or standards provided by users, the long-term hydrostatic performance and instantaneous blasting test of various pipes can be detected and judged, and the experimental data can be analyzed and processed, and the output can be printed.
II.Standards
GB/T6111-2018, GB/T15560-1995, GB/T18252-2008, GB/T18476—2001, ASTM D1598-2004, ASTMD1599, ISO1167, ISO13479, ISO9080, DIN EN 921 (1995-01), ASTM F1335
III. Technical data
Max.pressure | 16 MPa | |
Test stations | 2, 3, 4, 5, 6, 8, 10, 12 stations(can customize) | |
Control mode | computer and meter docuble control | |
Data preservation | Each station has power off data protection function, boot can be restored | |
Time | timing time | 0~9999 h 59 min |
Timing accuracy | ±0.1% | |
time resolution | 1s | |
Minimum Set Unit | min | |
Pressure | Pressure control range | 0.2~10MPa |
Pressure indicator units | MPa,bar or PSI | |
Pressure control accuracy | -1%~ +2% | |
Constant Voltage Control Precision of Full Load Range | Within ±1% | |
Pressure display resolution | 0.001MPa,0.01bar or 1PSI | |
measuring range | 4%~100%FS | |
Allowable error limit for indication | Within 1% |
IV.Configuration
1.Pressure control system;
2.Pressure supply system;
3.Test tank and temperature control system;
4.End closures: φ10~500mm(according to customers requirement).
5.Refrigeration system(according to customers requirement)