Product Details:
Payment & Shipping Terms:
|
Product Name: | XRW-300F Plastic Molds Heat Deformation HDT Vicat Tester | Controll: | By Computer |
---|---|---|---|
Test Station Moving Method: | Automatic | Mainframe Type: | Floor Type |
Vicat Load: | 10N ± 0.2 N , 50N ± 1N | Max. Deformation Deviation: | 0.001mm |
Deformation Measuring Rage: | 0 ~ 2.5mm | Sample Frame Number: | 3-6 Stations Can Be Selected |
Highlight: | hdt vicat tester,vicat testing machine |
XRW-300F Plastic Molds Heat Deformation HDT Vicat Tester
Description:
XRW-300 Heat Deformation hdt vicat tester manufactured based on the latest international standards and national standards, mainly for determination of the heat distortion temperature and Vicat softening point temperature of plastics, hard rubber, nylon, electrical insulation materials, long fiber reinforced composite materials, high strength thermosetting laminates and other non-metallic.
Features:
XRW-300F Plastic Molds Heat Deformation HDT Vicat Tester are designed to fit the rapid development of plastic industry and improve the level of material research and test. They adopt the newest international and national standards: ISO 75-1-1993 Plastics; determination of temperature of deflection under load, ISO306:1994 Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST), GB/T1633—2000 Thermoplastic materials - Determination of Vicat softening temperature (VST), and GB/T1634—2001 Plastics; determination of temperature of deflection under load. Controlled by computer, they are of stable performance, easy operation and high automation degree, which makes them the most advanced test instruments to measure deflection and Vicat softening temperature of non-metallic materials.
Technical parameter:
Model | XRW-300F |
Sample holder lift mode | Automatic lift |
Control method | Computer control software |
Temperature range | Room temperature ~ 300 ℃ |
Heating rate | 120 ° C / h, 50 ° C / h |
Maximum temperature error | ± 0.5 ℃ |
Temperature measurement point | 1 |
Sample station | 3~6 station can be selected |
Deformation measuring guage | Displacement transducer |
Deformation measurement range | 0 ~ 2.5mm |
Specimen support span | 64mm, 100mm (customized) |
Maximum deformation measurement error | 0.001mm |
Heating medium | Methyl silicone oil |
Cooling method | the natural cooling above 150 ℃, water or natural cooling below 150 ℃; |
Instrument size | 600mm*400mm*1400mm |
Power supply | 220VAC 50Hz |