Product Name: | A Device For Measuring The Deformation Temperature Of Plastic Under Load (bending Stress Under Three-point Loading) | Test Stations: | 6 |
---|---|---|---|
Heating Rate: | 120℃/h 、 50℃/h | Maximum Temperature Error: | ±0.5℃ |
Deformation Measurement Range: | -1.00~10.00mm | Span Of Sample Supports: | 64mm, 100mm |
Maximum Deformation Measurement Error: | 0.001mm | Current Source: | 6KW, 220VAC, 50HZ |
High Light: | Deformation Temperature hdt vicat testing machine,6 station hdt vicat testing machine,Deformation Temperature vicat testing machine |
The device is designed to fit the rapid development of plastic industry and improve the level of material research and test. They adopt the newest international and national standards: ISO 75-1-1993 Plastics; determination of temperature of deflection under load, ISO306:1994 Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST), GB/T1633—2000 Thermoplastic materials - Determination of Vicat softening temperature (VST), and GB/T1634—2001 Plastics; determination of temperature of deflection under load. Controlled by computer, they are of stable performance, easy operation and high automation degree, which makes them the most advanced test instruments to measure deflection and Vicat softening temperature of non-metallic materials.
Test load:
The weights should be chosen according to the calculated result. The weights should be placed evenly on the weight supporting plates.
(a) Heat deflection temperature test (Specimen placed flat)
Wherein
F: Test needed load (N)
σ: Standard required fiber stress (kPa)
A Method: σ=1800 kPa
B Method: σ=450 kPa
b: Specimen width (m)
h: Specimen thickness (m)
L: Span between the two supporting points of the sample frame (m)
(b) Vicat softening temperature test
There are two standard test loads:
A Method: 9.81N (using 1kg weight)
B Method: 49.05N (using 5 kg weight)
When coming out of the factory, the weight of load rod and supporting plate is 69g. If the sensor has spring, the load is all about 100g.
Test Standards:
ISO75-1 Plastic-Load Deformation Temperature ISO306 Determination of Temperature of Plastic-Thermoplastics
GB / T1633-2000 Determination of Temperature of VICAT
GB / T1634-2001 Plastic-Load Deformation Temperature
GB / T8802 Determination of Softening Temperature of Thermoplastic Pipe and Pipe
ASTM D 1525-1991 Test method for plastic ka softening temperature
ASTM D648-06 Test method for the deflection temperature of plastic under deflection load
Technical Parameter:
Temperature control range | Room temperature ~300℃ |
Heating rate | 120±10℃/h , 50±5℃/h |
Maximum temperature error | ±0.5℃ |
Temperature measurement point | 3 |
Test stations | 6 stations |
Loading | 10±0.2N, 50±1.0N |
Test frame lifting mode | Automatic rising-lowering |
Formal measurement measuring tool | Digital display dial gauge |
Deformation measurement range | -1.00~3.00mm |
Span of sample support | 100mm, 64mm |
Maximum deformation measurement error | 0.001mm |
Thermal expansion coefficient of specimen holder | <0.005mm/100℃ |
Heating medium | Silicone oils, glycerine, ethylene glycol, mineral oil |
Cooling method | >150℃ Natural cooling, ≤150℃ water cooling or natural cooling |
Temperature protection | Can stop heating automatically when test temperature reaches the upper limit. |
Equipment size |
910mm×560mm×1350mm |
Current source | 3KW, 220VAC, 50HZ |
Support and Services:
HDT VICAT Testing Machine provides a wide range of technical support and services to ensure peak performance and maximum uptime. We offer on-site installation services, operator training, preventive maintenance, and troubleshooting assistance.
Installation and SetupOur experienced technicians will install and setup the HDT VICAT Testing Machine at your site and provide operator training.
Preventive MaintenanceWe offer scheduled preventive maintenance services to ensure the optimal performance of the HDT VICAT Testing Machine.
Troubleshooting AssistanceWe provide troubleshooting assistance to help you identify and resolve any issues with the HDT VICAT Testing Machine.
Packing and Shipping:
The HDT VICAT Testing Machine is packed in a wooden box to ensure that it is safe and secure during transport. The wooden box is lined with bubble wrap and foam to protect the machine from any external damage. The machine is then sealed with a plastic wrap to protect it from moisture. The box is then labeled with the exact contents of the package so that it can be easily identified. The machine is then shipped using a reliable carrier such as UPS or FedEx.